All contracts

Robline Ocean STS

In plain English

Amended request for 8 mm Robline Ocean STS synthetic rope, part 7155408, including a 3,000-meter continuous length. Limited to small businesses; small-business resellers may supply the product. Full specs are in the attachments.

Agency: Dept Of Defense · Dept Of The Navy
Notice type: Combined Synopsis/Solicitation
Set-aside: Total Small Business
NAICS: 314994
Place of performance: Not listed
Posted: Oct 28, 2026
Response due: Oct 29, 2026
Solicitation number: N6660427Q0041

Open on SAM.gov

Get alerts like this one More from Dept Of Defense

Description

Amendment 0003 The purpose of this amendment to is to provide the following response to Industry question: Question 1: Amendment 0002 confirms part number 7155408 and states that 7152800 is obsolete. If the manufacturer�s certificate of conformance, technical data, or test report identifies part 7155408 as �Robtec STS� rather than �Ocean STS,� will that documentation be acceptable provided it clearly identifies part 7155408 and demonstrates compliance with every stated technical requirement? Answer 1: Yes. The documentation will be acceptable provided it clearly identifies part # 7155408. Question 2: Because the required 3,000-meter continuous length must be newly manufactured, may an offeror submit representative manufacturer-certified test documentation and a written manufacturer commitment with its quotation, followed by the actual production-lot certificate of conformance and certified test report with delivery? Or must the quotation include certified results for the specific production lot that will be delivered? Answer 2: The offeror may submit representative manufacturer- certified test documentation and a written manufacturer commitment with its quotation followed by the actual production-lot certificate of conformance and certified test report. Question 3: Must proof-load testing cover the entire continuous 3,000-meter length, or is the manufacturer�s standard lot-based or sample-based proof-load testing acceptable? Please confirm the applicable proof-load or sampling requirement. Answer 3: The Manufacturer�s standard lot-based or sample-based proof-load testing is acceptable. Question 4: For this total small-business set-aside, may an eligible small-business reseller supply the specified Robline product, or must the offered product be manufactured by a qualifying small-business manufacturer? If a class or individual waiver applies, please identify it. Answer 4: Any eligible small-business reseller may supply the specified Robline product for this total small-business set-aside under the SAT. Amendment 0002 The purpose of this amendment is to extend the respose period for this opportunity and to provide the following responses to Industry questions. Question 1: The combined synopsis identifies �Robline (Ocean) STS� 8 mm rope as part 7155408. Robline�s published catalog lists 7152800 for the 8 mm Ocean STS (Dyneema) variant and 7155408 for the 8 mm Robtec STS (HMPE) variant; both show 9,430 daN breaking load and about 47 g/m linear density. Answer 1: The required part number is 7155408. The number listed below (7152800) is an old part number and is now obsolete. Question 2: Please confirm whether the required product is the Robtec STS 7155408 or Ocean STS 7152800, and which product name must appear on the manufacturer CoC and test reports. The notice also specifies elongation no greater than 0.19% at 94.3 kN, which is the stated breaking-strength threshold. Please confirm the intended test load and method for that elongation figure so we …

Get opportunities like this one every morning.

Yia | Contract Alerts reads every new notice and emails you the matches for your NAICS codes, location and certifications, each with a fit score. 14-day free trial.

Start free