Source Sought for Schneider Electric PowerLogic ION8650 Power and Energy

In plain English

Navy market research at Joint Base Pearl Harbor-Hickam seeks other electrical meters matching the Schneider ION8650 specifications. Responses with technical data are invited by November 9, 2026; this is not a solicitation.

Agency: Dept Of Defense · Dept Of The Navy
Notice type: Sources Sought
Set-aside: No set-aside (open to all)
NAICS: 334515
Place of performance: Jbphh, HI
Posted: Nov 2, 2026
Response due: Nov 9, 2026
Solicitation number: N62478CON31FY2703

Open on SAM.gov

Get alerts like this one More from Dept Of Defense

Description

The Government intends to procure, under only one responsible source, where no other suppliers or service will satisfy the agency requirements. The Naval Facilities Engineering Systems Command, Hawaii (NAVFAC Hawaii) is conducting market research to determine if other potential products/services can provide for an electrical meter that has equal performance requirements as the Schneider Electric PowerLogic ION8650 Power and Energy, manufactured by Schneider Electric USA, Inc., 800 Federal St, Andover, MA 01810-1067. The alternate product/service must meet the following requirements/specifications: Listed on AF�s Advanced Meter Reading System (AMRS) Compliant Meter List Meter must comply with ANSI C12.1, NEMA C12.19, and ANSI C12.20 and must match existing AMRS reading system at the installation. Meter must be rated for use at temperature from minus 40 degrees Centigrade to plus 70 degrees Centigrade. The meters must have an electronic demand recording register and must be secondary reading as indicated. The register must be used to indicate maximum kilowatt demand as well as cumulative or continuously cumulative demand. Demand must be measured on a block-interval basis and must be capable of a 5 to 60 minute interval and initially set to a 15-minute interval. It must have provisions to be programmed to calculate demand on a rolling interval basis. Meter readings must be true RMS. The meter electronic register must be of modular design with non-volatile data storage. Downloading meter stored data must be capable via an optical port. Recording capability of data storage with a minimum capability of 89 days of 15 minute, 2 channel interval data. The meter must be capable of providing at least 2 KYZ pulse outputs (dry contacts). Meter must have an optical port on front of meter. Optical device must be compatible with ANSI C12.18. Meters must be 120-480 volts auto ranging. Power Quality: sag/swell, individual, even, odd, total harmonics to the 31st and symmetrical components 9S, 35S, 36S socket and switchboard cases True RMS 3-phase voltage, current, power and meets ANSI revenue metering standards including ANSI C12.20 0.2 and Class 2, 10, & 20. This notification is for market research purposes only and should not be construed as a commitment of any kind by the U.S. Government to issue a solicitation, request for proposals, quotes, or invitation of bids or award a contract. Interested parties with a comparable product meeting the requirements described in this announcement are invited to submit complete technical data, information and specifications in order for the Government to conduct an evaluation of your product to ensure compatibility with the existing system. Technical response shall be typed, at least 11 point Times New Roman or larger, single-sided 8.5 by 11 inch pages and submitted in Adobe PDF format. Also, provide company information and point of contract (name, title, email, phone, mailing address). The Government will not reimburse any r…

Get opportunities like this one every morning.

Yia | Contract Alerts reads every new notice and emails you the matches for your NAICS codes, location and certifications, each with a fit score. 14-day free trial.

Start free