VA Greater Los Angeles seeks information on suppliers of Air Innovations SSC4500DX sterile storage cabinets with installation. Cabinets must have UV-C sterilizing light, remote monitoring, and set temperature and humidity ranges. Information only, not a solicitation; manufacturer size limit 1,000 employees.
Get alerts like this one More from Veterans Affairs, Department Of
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES. DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113, Surgical Appliances and Supplies Manufacturing (size standard of 1,000 employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs Network Contracting Office 22 is seeking a contractor to provide Air Innovations SSC4500DX Sterile Storage Cabinets and Installation for the Greater Los Angeles VAMC, Los Angeles, CA. The prospective contractor must be able to provide supplies that meet or exceed the following requirements: STERILE STORAGE CABINET SALIENT CHARACTERISTICS The Sterile Storage Cabinets must have UV-C light is located above the HEPA filter and floods the filter with intense UV-C rays, which will sterilize airborne viruses and bacteria on the HEPA filter. The Sterile Storage Cabinets must allow user(s) to remotely monitor the temperature, humidity, and pressure of the Sterile Storage Cabinet from another room through 0-10 VDC signal. The Sterile Storage Cabinets must exceed requirements of VA Directive 1116(2); ANSI/AAMI ST79-2006; ANSI/ASHRAE/ASHE Standard 170-2017. The Sterile Storage Cabinets must conform with UL60601-1. The Sterile Storage Cabinets must be able to maintain 66°F to 72°F Temperature. The Sterile Storage Cabinets must maintain Humidity at 20% to 60% RH. The Sterile Storage Cabinets must have steam humidification utilizing standard demineralized water. The Sterile Storage Cabinets must maintain positive pressure of +0.03 WC. The Sterile Storage Cabinets must meet IEC 60601-1, Medical Standard for Power Supplies. The Sterile Storage Cabinets must have 120V hospital grade plug-in-cord. The Sterile Storage Cabinets must have cleanable 304 stainless steel payload construction with cleanable white powder coated. The Sterile Storage Cabinets must have HEPA Filtration designed to exceed ISO 6 Cleanliness. The …
Yia | Contract Alerts reads every new notice and emails you the matches for your NAICS codes, location and certifications, each with a fit score. 14-day free trial.
Start free