Veterans Affairs seeks businesses able to replace two dental vacuum pumps and their control system in Building 3 at the Carl Vinson VA Medical Center in Dublin, Georgia. Work requires certified medical gas installers. Small business set-aside is possible; veteran-owned firms especially invited to respond.
Get alerts like this one More from Veterans Affairs, Department Of
SOURCES SOUGHT / REQUEST FOR INFORMATION Building 3 Dental Vacuum Pump Replacement Carl Vinson VA Medical Center, Dublin, Georgia PROPOSED NAICS: 811210 Electronic and Precision Equipment Repair and Maintenance PROPOSED PSC: J065 Maintenance, Repair, and Rebuilding of Medical, Dental, and Veterinary Equipment and Supplies PURPOSE The Department of Veterans Affairs, Network Contracting Office 7, is conducting market research to identify businesses capable of performing the Building 3 Dental Vacuum Pump Replacement requirement at the Carl Vinson VA Medical Center. Responses are requested from all interested businesses, particularly SBA-certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and Veteran-Owned Small Businesses (VOSBs). Information received will assist the Government in determining the appropriate acquisition strategy, including potential set-aside opportunities. No set-aside determination has been made. REQUIREMENT The contractor shall provide all labor, supervision, materials, equipment, tools, transportation, and technical expertise necessary to replace two existing dental vacuum pumps and the associated control system in the attic of Building 3. The anticipated work includes: Site assessment and preparation. Safe disconnection, removal, and disposal of existing pumps, obsolete controls, and associated components. Supply and installation of two replacement dental vacuum pumps. Supply and installation of a compatible replacement control and monitoring system. Necessary piping adjustments, electrical connections, control wiring, and integration with the existing dental vacuum system. Operational testing, leak testing, verification, and demonstration of the completed system. Delivery of operating manuals, maintenance information, warranty documentation, and applicable as-built documentation. The SOW identifies minimum pump performance requirements, including a minimum rated capacity of 80 CFM at 7 inches Hg, support for at least 10 simultaneous users per pump, and compatibility with existing 208/230V three-phase electrical service. Replacement equipment may be from any manufacturer that meets the SOW s performance and compatibility requirements. The existing RAMVAC Bison 9 pumps and OWL controller are identified for reference. The SOW requires personnel performing installation to hold current ASSE 6010 Medical Gas Systems Installer certification. Respondents should identify their ability to meet this requirement and describe any recommended clarification of its applicability. See the attached SOW for complete requirements. LOCATION AND COMPLETION PERIOD Carl Vinson VA Medical Center Building 3, Dental Services 1826 Veterans Boulevard Dublin, GA 31021 The anticipated completion period is 90 calendar days after award. Respondents should identify equipment lead times and any conditions that could affect this schedule. Work may require coordination for evenings or weekends to minimize disruption to patient care. REQUESTED RESP…
Yia | Contract Alerts reads every new notice and emails you the matches for your NAICS codes, location and certifications, each with a fit score. 14-day free trial.
Start free