Veterans Affairs seeks information on service-disabled veteran-owned small businesses able to install continuous water monitoring equipment in five buildings at Jefferson Barracks VA Medical Center, St. Louis. Restricted to SDVOSB firms; market research only, no solicitation yet.
Get alerts like this one More from Veterans Affairs, Department Of
657-27-111JB, Install Continuous Water Monitoring System This is a Sources Sought Notice to determine the availability of service disabled veteran owned small business (SDVOSB) firms for a possible small business category type set-aside for Construction Services project: This is a Sources Sought Notice that is issued for information and planning purposes only and is not to be construed as a commitment� by the government, implied or otherwise to issue a solicitation or ultimately award a contract.� An award will not be made on information received in response to this notice.� This notice is not a Request for Proposal (RFP); it is a market research tool being utilized to determine the availability of sources prior to issuing a Best Value type RFP. PROJECT DESCRIPTION AND SCOPE This project will install continuous monitoring equipment for biocides, PH level, pressure and temperature at domestic cold water sources and hot water generation for VHA DIR 1061 Buildings, additional temperature sensors on the hot distribution will be installed at mid-point and end-of-line for each major distribution system of the buildings. Data will be back net capable for Building automation system (BAS) VA Johnson controls tie-in and real-time monitoring. Scope includes: JB Bldgs 3, 51, 52, 53, 59 Jefferson Barracks VAMC: Building 3: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 51: 1 incoming cold water continuous monitoring with pressure and temperature 2 cold water distal -Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 52: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 53: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 59: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source …
Yia | Contract Alerts reads every new notice and emails you the matches for your NAICS codes, location and certifications, each with a fit score. 14-day free trial.
Start free